EXP (900 series)
Heavy duty bellows (S/S) pressure switch with high shock and vibration resistance. Ranges -0.9 to +40 bar. G1/4” (F) process connection in S/S, with fixed switching differential. Internal setting. M20x1.5 WS22 cable gland to IP65. Also available as “simple apparatus” for Ex-i applications. |
 |
EXPK (944 series)
Heavy duty piston pressure switch with high shock and vibration resistance. Ranges +1..+400 bar. G1/4” (F) process connection in S/S, with fixed switching differential. Internal setting. M20x1.5 WS22 cable gland to IP65. Also available as “simple apparatus” for Ex-i applications. |
 |
EXPD (920 series)
Heavy duty bellows S/S differential pressure switch with high shock and vibration resistance. Ranges -0.6 to +16 bar differential. 2 x G1/8” (F) ports in S/S with fixed switching differential. Internal setting. M20x1.5 WS22 cable gland to IP65. Also available as “simple apparatus” for Ex-i applications. |
 |
EXAS (414 series)
Heavy duty ambient thermostat. Ranges between -30..+60 Celsius with fixed switching differential. Epoxy coated aluminium housing. Internal adjustment. M20x1.5 WS22 cable gland to IP65. Also available as “simple apparatus” for Ex-i applications. |
 |
EXS (414 series)
Heavy duty thermostat. Ranges between -30 to +350 Celsius with fixed switching differential. Epoxy coated aluminium housing. Internal adjustment. M20x1.5 WS22 cable gland to IP65. Standard capillary (S/S) length 2 metres, other lengths possible, also direct mounted version possible. Also available as “simple apparatus” for Ex-i applications. |
 |
KTSB series
Heavy duty thermostat with high current (16 A) and mechanical reset. Ranges +20 to +350 Celsius with fixed switching differential. Rugged plastic case to IP66. M20x1.5 WS22 cable gland to IP65. Standard capillary (S/S) length 2 metres, other lengths possible. Enclosures of polyester, aluminium, stainless steel or carbon steel, depending on version. |
 |
EXNA (8852 series)
Pressure transmitter with piezio resistive sensor, high shock and vibration resistance. Ranges 0..+100 mbar to 0..+1000 bar, 4-20mA out. Media temperatures to T3; T4: T6, accuracy 0.5% FS NLH (BSL) process connection G1/4” (M), available with G1/2” (M) flush or frontal diaphragm. Electrical connector EN175301-803 large 90 degree connector to IP65. |